Lab.gruppen Lake Controller troubleshooting
The Lab.gruppen Lake Controller problems live-event techs bring to Ask Roadie most (also called Lake, Lake LM26, Lake LM44). Pick your symptom, or describe your own in plain words, and get the likeliest fix first, with the manual page when there is one.
Common Lake Controller errors & problems
What techs run into most, and what's usually behind it. The step-by-step fix for your exact software is in Ask Roadie.
- Step-by-step fixGet the fix →
Amp reports Mains Fault
Likely cause: The PSU monitors incoming mains and faults out to protect itself when the supply is out of spec.
- Step-by-step fixGet the fix →
Amp shows NEEDS SERVICE:4 or DICO COMM FAULT for no clear reason
Likely cause: A firmware bug tripped an internal DICO/service fault falsely; the fixed firmware corrects the state logic.
- Step-by-step fixGet the fix →
Analog input/output hum or ground loop
Likely cause: Iso-Float electrically isolates the analog reference so a ground-potential difference no longer drives hum current through the signal.
- Step-by-step fixGet the fix →
Channel LED steady red with VHF FAULT
Likely cause: A dedicated VHF detector mutes the channel to protect compression drivers from sustained ultrasonic energy.
- Step-by-step fixGet the fix →
How do I update firmware on a PLM/D or LM device?
Likely cause: LakeUpdate flashes the frame firmware to the version bundled with the installed Controller; interrupting power can brick the module.
- Step-by-step fixGet the fix →
How to set Dante network redundancy on LM/LMX
Likely cause: Dual Redundancy carries the same Dante flow on two isolated networks so a cable/switch failure switches over without audio interruption.
- Step-by-step fixGet the fix →
Lake Controller opens but Frames will not appear even on the same subnet
Likely cause: Lake discovery/control traffic is blocked by the firewall or sent out the wrong NIC; allowing both profiles and binding the right adapter restores discovery.
- Step-by-step fixGet the fix →
Old firmware notification / frame will not come fully online after a Controller upgrade
Likely cause: The Controller refuses full control of a frame whose firmware protocol differs; matching versions restores it.
- Step-by-step fixGet the fix →
Recall a whole system to a known state
Likely cause: System files snapshot every module and group so a full rig returns to a verified state in one recall.
- Step-by-step fixGet the fix →
TEMP WARN:CH or TEMP FLT:PSU over-temperature
Likely cause: The amp derates then mutes to protect the output stage/PSU from thermal damage; restoring cooling clears it.
- Step-by-step fixGet the fix →
Which Lake Controller version / firmware should I run?
Likely cause: Controller and device firmware are versioned together; a mismatch shows frames offline or partly-standby.
Not on the list? Describe it your way, or paste the error code off the display. Ask Roadie works the problem with you until it's fixed or you have a clear next move.
How Ask Roadie helps with the Lake Controller
- 1. Pick the Lab.gruppen Lake Controller. It's already in the list.
- 2. Describe what you're seeing. In your own words, or the error code off the screen.
- 3. Get the likeliest fix first. Steps in order, the manual page when there is one, and a note when other techs have confirmed it.
- 4. Still broken? Tap 👎 and it keeps going from where you left off.